Show simple item record

dc.contributor.authorEdwin, Stanley G.
dc.date.accessioned2022-05-13T17:52:55Z
dc.date.available2022-05-13T17:52:55Z
dc.date.issued2020-08
dc.identifier.urihttp://hdl.handle.net/11122/12877
dc.descriptionDissertation (Ph.D.) University of Alaska Fairbanks, 2020en_US
dc.description.abstractHow healthy is the air in the villages during the summer fire seasons? Why does Fort Yukon always seem to be colder than the surrounding villages in winter and spring? How healthy is the air we breathe in our homes and workplaces? These are but a few of the questions asked by Alaska's Eastern Interior residential village's Indigenous Tribal Governments. A tribal-owned network of aerosol monitors and meteorological stations was installed at Ts'aahudaaneekk'onh Denh, Gwichyaa Zheh, Jałgiitsik, and Danzhit Khànlaj̜j̜ in the Yukon Flats, Alaska. To assess the exposure of residents in rural communities in the Yukon Flats to particulate matter of 2.5 [micro]m or less in diameter (PM2.5), both indoor and outdoor concentration observations were carried out from spring 2017 through to August 2019. Surface-based-temperature inversions occurred under calm wind conditions due to surface radiative cooling. In May, local emissions governed air quality with worst conditions related to road and river dust. As the warm season progressed, worst air quality was due to transport of pollutants from upwind wildfires. Absorption of solar radiation in the smoke layer and upward scattering enhanced stability and fostered the persistence of the surface-based-temperature inversions. Under weak large-scale forcing mountain-valley circulations develop that are driven by the differences in insolation. During the long dark nights, surface radiative cooling occurs in the near-surface layer of the mountain slopes of the Brooks, Ogilvie and White Mountains Ranges and at the bottom of the valley. Here surface-based-temperature inversion - known as roof-top inversions - form, while the cold air drains from the slopes. A frontal wedge forms when the cold air slides over the relatively colder air in the valley. Drainage of cold air from the Brooks Range governed the circulation and cold air pooling in the valley. At the site, which is closest to the mountains, concentrations marginally changed in the presence of temperature inversions. Indoor concentrations were measured at 0.61 m in homes and at 1.52 m heights both in homes and office/commercial buildings. Air quality was better at both heights in cabins than frame homes both during times with and without surface-based-temperature inversions. During summer indoor concentrations reached unhealthy for sensitive groups to hazardous conditions for extended times that even exceeded the high outdoor concentrations. Indoor and outdoor concentrations were strongest related for office/commercial buildings, followed by frame houses and cabins. These are but a few of the answers found in this research of meteorology effects, unhealthy locations for breathing PM2.5 air outdoors and in homes.en_US
dc.description.sponsorshipTribal Resilience Programen_US
dc.description.tableofcontents1. Introduction -- 1.1. Motivation -- 1.2. Goals -- 1.2.1. Four regional villages of the Yukon Flats Valley -- 1.2.2. Largest and central village of the Yukon Flats: indoor-outdoor -- 1.3. Logistics for research in rural Alaska areas -- 1.4. Instrumentation -- 1.5. Design modification for instrument placement -- 1.5.1. In-situ site design for the four villages, a regional monitoring of the Yukon Flats -- 1.5.2. Single village monitoring: modification of indoor monitors -- 1.6. Site locations for regional and single village -- 1.6.1. Four regional village locations -- 1.6.2. Single village locations for indoor vs. outdoor air quality -- References -- 2. Particulate matter exposure of rural interior communities as observed by the first tribal air quality network in the Yukon Flat -- 3. Mesoscale impacts on cold season PM2.5 in the Yukon Flats -- 4. Indoor and outdoor particulate matter exposure of rural Interior Alaska residents -- 5. Conclusion -- Dedication -- Acknowledgements -- Appendix.en_US
dc.language.isoen_USen_US
dc.subjectAir qualityen_US
dc.subjectFort Yukonen_US
dc.subjectChalkyitsik Villageen_US
dc.subjectYukon Flats National Wildlife Refugeen_US
dc.subjectIndoor air qualityen_US
dc.subjectTemperature inversionsen_US
dc.subjectBeaver, Alaskaen_US
dc.subjectCircle, Alaskaen_US
dc.subject.otherDoctor of Philosophy in Atmospheric Sciencesen_US
dc.titleCurrent exposure of Yukon Flats tribal villages' residents to PM₂.₅ from natural and anthropogenic sources: establishing baselines for climate change adaptation and resilienceen_US
dc.typeDissertationen_US
dc.type.degreephden_US
dc.identifier.departmentDepartment of Atmospheric Sciencesen_US
dc.contributor.chairMölders, Nicole
dc.contributor.committeeCollins, Richard L.
dc.contributor.committeeFochesatto, Javier
dc.contributor.committeeStuefer, Martin
refterms.dateFOA2022-05-13T17:52:56Z


Files in this item

Thumbnail
Name:
Edwin_S_2020.pdf
Size:
18.82Mb
Format:
PDF

This item appears in the following Collection(s)

Show simple item record