    Developing a proof-of-concept non-scalable active vacuum insulated building envelope prototype

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Thumbnail
    Name:
    Strailey_K_2025.pdf
    Size:
    4.396Mb
    Format:
    PDF
    Download
    Author
    Strailey, Kaarle P.
    Chair
    Marsik, Tom
    Huang, Daisy
    Committee
    Bray, Matthew
    Keyword
    Insulation (Heat)
    Technological innovations
    Metadata
    Show full item record
    URI
    http://hdl.handle.net/11122/15990
    Abstract
    Heating and cooling buildings consumes around 17% of global energy demand. Improved thermal insulation can reduce much of this consumption with positive implications for energy security and economic opportunity. For over 25 years vacuum insulation panels (VIPs) have been considered a highly promising thermal insulation solution for building envelopes. VIPs can potentially provide an order of magnitude greater insulative performance than common insulation materials with the same thickness. However, the adoption of VIPs in buildings is hindered by many factors: their relatively high costs, installation challenges due to fragility, inalterability, and limited dimensions; limited service life in comparison to buildings due to loss of vacuum over time; susceptibility to thermal bridging along their edges; and other issues. An innovative concept in vacuum insulation technology, active vacuum insulation, is being developed to address many of these challenges. Incorporating a connection to a vacuum pump enables use of cheaper materials and equipment for on-site assembly and evacuation of customizable, large (for example, a whole wall) active vacuum insulation panels (active-VIPs). Vacuum can be extended indefinitely through occasional reactivation of the vacuum pump. For the project described in this thesis, a proof-of-concept active vacuum insulated building envelope prototype was developed. Large active-VIPs were produced and integrated with a vacuum assembly that created, monitored, and maintained internal vacuum. Over a one month trial period an average pressure of about 68 mTorr was maintained and the average R-value per inch of the active-VIPs was around 50 hr∙ft2∙°F∕Btu∕in. This was achieved using a minimal amount of electrical energy for the vacuum pump, representing less than 5% of the thermal energy saved thanks to the vacuum pump. These results indicate that active vacuum insulation is a worthwhile innovation for continued investment in research and development.
    Description
    Thesis (M.S.) University of Alaska Fairbanks, 2025
    Table of Contents
    Chapter 1: Introduction -- 1.1 Overview -- 1.2 Research goal and objectives -- 1.3 Scope and limitations -- 1.4 Thesis organization -- 1.5 Explanations and definitions -- Chapter 2: Literature review -- 2.1 Global energy context -- 2.2 Vacuum insulation technology overview -- 2.2.1 History of vacuum insulation -- 2.2.2 Vacuum insulation principles -- 2.2.3 VIP components and assembly -- 2.3 Obstacles to wider adoption of VIPs for building insulation -- 2.4 Potential solution: active vacuum insulation -- Chapter 3: Developing the active vacuum insulated building envelope prototype -- 3.1 Design considerations -- 3.2 General design -- 3.2.1 Protecting the floor panel and supporting the ceiling panel -- 3.2.2 Vacuum assembly -- 3.3 Assembling the active vacuum insulated building envelope prototype -- 3.3.1 Panel construction -- 3.3.2 Active vacuum insulated building envelope prototype assembly -- 3.4 Results -- Chapter 4: Evaluating thermal resistivity of active VIPs -- 4.1 Methods -- 4.1.1 Instrumentation and installation -- 4.1.2 General operation -- 4.2 Calculations and results: time averaged R-value per inch of prototype active-VIPs -- 4.2.1 Active-VIP R-value per inch calculated from effective R-value of the prototype -- 4.2.2 Representative Center of Panel (COP) R-value per inch obtained from heat, flux measurements -- 4.2.3 Discussion -- 4.3 Evaluating the relationship between active-VIP thermal resistivity and internal pressure -- 4.3.1 Discussion -- Chapter 5: Energy consumption of vacuum pressure maintenance and net energy implications -- 5.1 Methods and results -- 5.2 Discussion -- Chapter 6: Conclusions and recommendations -- 6.1 Conclusions -- 6.2 Recommendations -- References.
    Date
    2025-05
    Type
    Thesis
    Collections
    Interdisciplinary Studies
    Engineering

    entitlement

     
    ABOUT US|HELP|BROWSE|ADVANCED SEARCH

    The University of Alaska is an affirmative action/equal opportunity employer, educational institution and provider and prohibits illegal discrimination against any individual.

    Learn more about UA’s notice of nondiscrimination.

    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.