Document Type
Technical Report
Abstract
This report documents and presents the results of a study aimed at developing a structured insulation layer with asymmetric thermal resistance properties for use in roadway embankments installed over permafrost foundation soils. EPS or XPS foam insulation board is modified by including specially designed air cavities that allow for circulation of the cavity air during winter conditions. The cavity air circulation greatly increases heat transfer rates through the insulation layer during winter, thus providing an enhanced cooling effect for the foundation soils. During summer, stable air density stratifications prevail within the cavities and no air circulation occurs, thus increasing the thermal resistance of the insulation and avoiding summer heat gain in the foundation soils. The structured insulation layer is thus able to provide a passive cooling effect that chills the foundation soils and permafrost layer during each winter season while limiting summer heat gain. Numerical simulations and experimental laboratory studies are utilized to demonstrate that the proposed system should be capable of reducing or eliminating thaw settlement problems beneath roadway embankments installed in areas underlain by warm permafrost.
Publication Date
Fall 11-2026
Recommended Citation
Goering, Douglas J., "Roadway Foundation Cooling Using Structured Foam Insulation Layers" (2026). AIDC Project Reports. 143.
https://scholarworks.alaska.edu/uaf_aidc_project_reports/143